Underfloor heating calculator

Enter the area, the number of rooms and the system. The calculator gives metres of pipe, loops and coils, edge strip, insulation and screed, and the installed cost per m² and in total.

Advertisement

1. Area and system

Advertisement

2. Water system: pipe and insulation

3. Electric system

4. Screed

Result

Pipe in total
Loops / manifold circuits
Pipe per 1 m²
Coils of 200 m
Underfloor heating cost per m²
–
Edge stripInsulationScreedThermostats (zones)Area with heatingElectric power
Estimated installed cost
–
Unit prices are indicative (2026) and editable – enter your own shop or quote price.
Advertisement

Cost summary

ItemQuantityCost

How we calculate

Water system: pipe per 1 m² = 100 ÷ spacing in cm (10 cm gives 10 m, 15 cm gives 6.7 m, 20 cm gives 5 m). Loops = metres of pipe ÷ (max. loop length − 2 × run to the manifold), rounded up. The runs and a 3% reserve are added and the result is split into 200 m coils. The edge strip is the sum of the room perimeters. Insulation and screed: area × thickness. Electric: area × share of free floor × output per m².

Prices are indicative and editable. Poland: water system 180–290 PLN/m² net installed (without screed), anhydrite screed 45–70 PLN/m² (our 2026 price list). Sweden: water about 1,000–2,000 SEK/m², electric about 750–1,500 SEK/m² (Offerta, 2025). Prices for other markets are approximate. The calculator does not replace a heating design: loops and spacing are chosen by the designer from the heat demand.

Advertisement
Advertisement

How the calculator works – questions and answers

How much does underfloor heating cost per m² in 2026?

In Poland a water system with materials and labour costs 180–290 PLN per m² net, and anhydrite screed another 45–70 PLN per m². For 100 m² that is about 23,500 PLN for the system and 5,800 PLN for the screed. In Sweden Offerta quotes about 1,000–2,000 SEK/m² for water and 750–1,500 SEK/m² for electric systems.

How many metres of pipe per 1 m²?

At 10 cm spacing you need 10 m of pipe per 1 m², at 15 cm about 6.7 m and at 20 cm 5 m. Add the runs from the manifold to each loop.

What is the maximum loop length?

For 16 mm pipe the usual limit is 100 m including the run to the manifold, and about 120 m for 17–20 mm pipe. Longer loops have too much resistance and heat unevenly, so larger rooms are split into several loops of similar length.

Which pipe spacing: 10, 15 or 20 cm?

A 10 cm spacing is used in bathrooms and along large glazing, 15 cm in most rooms and 20 cm in well-insulated houses only when the design confirms it. Closer spacing allows a lower flow temperature.

Water or electric underfloor heating?

Water systems cost more to install but less to run and work with a heat pump, so they pay off for a whole house. Electric mats and foil are cheaper to fit and suit single rooms such as a renovated bathroom. The electrical connection must be made by a qualified electrician.

Need a contractor?Describe your job – free

The tool is free and runs in your browser – nothing is sent to a server.